DMSNetworkStatus.Voltage

JSON structure

{

  // *** Messages MUST be encoded in UTF-8! ***

  // --- Fields of AbstractMessage begin ---
  "Type" : "set-message-type-here",
  "Timestamp" : "2020-06-03T04:04:21.045Z",
  "SimulationId" : "2020-06-03T04:01:52.345Z",
  "SourceProcessId" : "set-process-id-here",
  "MessageId" : "set-message-id-here",
  // --- Fields of AbstractMessage end ---

  // --- Fields of AbstractResult begin ---
  "EpochNumber" : 14,
  "IterationStatus" : "final", // leave out when not iterating
  "LastUpdatedInEpoch" : 14, // OPTIONAL field
  "TriggeringMessageIds" : // TriggeringMessageIds are irrelevant in Epoch messages?
  [
    "epoch-14",
    "someprocess-14",
    "anotherprocess-14"
  ],
  "Warnings" : // If warnings precede an error, it can be beneficial to provide them as well in the Error message
  [
    "warning.convergence"
  ],
  // --- Fields of AbstractResult end ---

  "VoltageStatus":[
      {
       "BusName":"sourcebus",
       "Node":1,
       "Status":"close-to-limits"
       "Violation":0
      },
      {
       "BusName":"sourcebus",
       "Node":2,
       "Status":"close-to-limits"
       "Violation":0
      }
     ]
}

Fields and multiplicity

Field Type Multiplicity Notes
All fields from AbstractResult Fields from "abstract base class"
VoltageStatus Voltage table block 1 (REQUIRED)

Voltage table block

Field Type Multiplicity Notes
BusName String 1 (REQUIRED) BusNames are the same as defined in Init.NIS.NetworkBusInfo
Node Integer 1 (REQUIRED) Node values can be: 1, 2, 3
Status String 1 (REQUIRED) State values can be: acceptable, close-to-limits, unacceptable
Violation Float 1 (REQUIRED) The value can be : 0 for acceptable and close-to-limits states, positive for over-voltage state, negative for under-voltage state